Place of Origin: | Guangdong, P.R.C. |
Brand Name: | Basda Medical |
Certification: | ISO9001, ISO13485 |
Model Number: | BMP-15A |
Minimum Order Quantity: | 10 |
---|---|
Price: | Negotiable |
Packaging Details: | 1 unit/carton, 345mm*310mm*380mm |
Delivery Time: | Various by Logistics and Custom |
Payment Terms: | Credit card, Paypal, T/T, Western Union, MoneyGram |
Supply Ability: | 3 Days per 10 Units |
Application: | SPO2, 2TEMP, ECG, RESP, NIBP, PR, 2IBP, CO2 | AC: | 100-240V |
---|---|---|---|
Power Supply: | Built-in Battery | Material: | Plastic, Steel |
Form: | Standing | After-Sale Service: | Online Technical Support Or Replacement |
High Light: | Multi Parameters Patient Monitoring Machine,240VAC Patient Monitoring Machine,240VAC patient monitoring device |
Special Features for Luxury Edition
Parameter | |
Special Feature |
Internet connectivity slot 15-Inch TFT LED Color Touch screen Themal recorder Wi-Fi and Bluetooth 2-BP, C O Etco, Multi-gas, BIS, NMT 12-Lead ECG VGA |
Thermal Paper | Roll Paper with 50 mm*30m |
Detailed Configuration
Parameter | Configuration |
ECG |
Lead Mode 3-lead and 5-lead are optional Lead Selection I, II, III, AVR, AVL, AVF, V Wave 5-lead: 2 channels 3-lead: 1channel Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV |
CMRR |
Monitor ≥ 100 dB Surgery ≥ 100 dB Diagnosis ≥ 60 dB |
Bandwidth | Surgery 1 ~ 20 Hz(+0.4dB,-3dB) Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB) Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB) Calibration Signal 1 mV (Vp-p), ±5% Accuracy |
ST Segment Monitoring | Measuring and Alarm Range -0.6 mV~ + 0.8 mV |
ARR | ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
Alarm | Available |
Review | Available |
Scan Speed for ECG Waveform is adjustable | 12.5mm/s accuracy ±10% 25mm/s accuracy±10% 50mm/s accuracy±10% |
Respiration |
Method R-F(RA-LL) Impedance Differential Input Impedance >2.5 MΩ Measuring Impedance Range 0.3~5.0Ω Baseline Impedance Range 100Ω– 2500Ω Bandwidth 0.3 ~ 2.5 Hz |
Resp. Rate | Measuring and Alarm Range 0~120rpm Resolution 1 rpm Measuring Accuracy ±2 rpm Alarm Accuracy ±3rpm Apnea Alarm 10 ~ 40 S |
NIBP | Method Oscillometry Mode Manual, Auto, continuous Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10~270mmHg Alarm Type SYS, DIA, MEAN |
Resolution | Pressure 1mmHg Cuff Pressure ±3 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg |
SPO2 | Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2% 0% ~ 69% unspecified |
Pulse Rate(PR) | Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm |
TEMP | Channel dual-channel Measuring and Alarm Range 0 ~ 50°C Resolution 0.1°C Accuracy ±0.1°C Actualization Interval about 1 Sec. Average Time Constant < 10 Sec. Alarm responding Time ≤2min |
ETCO2 | Method Sidestream or Mainstream Measuring Range for CO2 0~150mmHg Resolution for CO2: 0.1 mm Hg 0 to 69 mm Hg 0.25 mm Hg 70 to 150 mm Hg Accuracy for CO2: 0 – 40 mm Hg ±2 mm Hg 41 – 70 mm Hg ±5% 71 – 100 mm Hg ±8% 101 – 150 mm Hg ±10% Respiration Rate>80BPM ±12% AwRR Range 2~150 rpm AwRR Accuracy ±1BPM Apnea Alarm Available |
IBP | Channel dual-channel Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range -50~350 mm Hg Resolution 1 mm Hg Accuracy ±2% or 1mm Hg, which is greater |
They come with the main machine