Place of Origin: | Guangdong, P.R.C. |
Brand Name: | Basda Medical |
Certification: | CE, ISO13485 |
Model Number: | Bstar-070 |
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | 1 unit/wooden box |
Delivery Time: | 30-45 Days |
Payment Terms: | Credit card, Paypal, T/T, Western Union, MoneyGram |
Supply Ability: | 200 Machines per Year |
First Launched: | 0.7T Superconducting MRI | Liters Of Liquid Helium: | Less Than 120 L |
---|---|---|---|
Field Strength Of The Magnet: | 0.7 Tesla | Cooling Technology: | Air Cooling |
Table Load: | Up To 320kg | Product Shape: | Panorama Open Shape |
High Light: | Panorama open end MRI machine,0.7T open end MRI machine,0.7 Tesla wide open mri machine |
• First open type superconductive MRI in the world
• No claustrophobia
• Liquid helium zero consumption technology
• Rich clinical application
Evolution Magnet Compared To Conventional Permanent Magnet:
The magnet, as one of the most important parts in MRI systems, determines the magnetic resonance image resolution and system level. Right now in the market, the magnet strength is classified by 2 types:
A, Permanent MRI;
B, Superconductive MRI.
The conventional superconducting magnets (most are 1.5T MRI system) are basically using bore design, this kind of design is not friendly for patients, very easy to cause the claustrophobic.
The magnet strength of permanent magnet has the bottleneck at 0.5T level due to the eddy current problem.
Bstar-070 uses the landmark 0.7T superconducting magnet, solve all above problems.
In the magnet structure, Bstar-070 uses liquid helium get the superconductive environment, and equipped by multiple Helmholtz superconducting coil charging with current to generate the magnetic field, the magnetic field strength is 0.7T.
The Helmholtz coil is made of a number of same radius coil, the coils are coaxial concatenated placed.
The coil array can generate up to dozens tesla's magnetic field. The main characteristics of this magnet are as followings:
A, very large open space;
B, very good magnet stability without the interference of magnet temperature.
C, very good magnet field homogeneity.
D, Liquid helium only 120L, much better than any 1.5T MRI system.
E, 46cm magnet gap, even better than permanent MRI system.
F, perfectly support the MRI intervention operations.
The magnet system config with two sets of superconducting coil, inside set and outside set. The inside coil is used to generate the magnetic field, the outside coil is used to limit the scope of magnet field, nameed "magnet curtain technology", with this technology the magnetic field can be limited in the range at minimum range. Two sets of coils are well connected to ensure the reliability and security of the system, together with dynamic shimming technology, the system can perform well at any time.
Conventional superconductive MRI uses water-cooled helium compressor, the helium compressor need to continue working to keep the magnet temperature at superconductive environment, its cost on the electricity and water is a very large. Bstar-070 innovatively uses the air-cooled helium compressor, greatly reduce the electricity bills, and zero water consumption, help the user to save money.
Due to COVID-19 Pandemic, the price of magnetic material increases sharply which thus pushes up the price of the permanent magnet MRI system. Basda the world first launched open type 0.7T superconducting MRI is a best substitution for the permanent magnet MRI system.
Contact Person: Peng
Tel: +86-13632708845
Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.
Factory Address:Block 1B, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.