Place of Origin: | China |
Brand Name: | BASDA |
Certification: | NMPA, ISO9001, ISO13485 |
Model Number: | BTH-50S |
Minimum Order Quantity: | 1 |
---|---|
Price: | Negotiable |
Packaging Details: | 1 unit/form package in wooden box |
Delivery Time: | 5-8 Work Days |
Payment Terms: | Credit card, Paypal, T/T, Western Union, MoneyGram |
Supply Ability: | 100 Units Per Month |
Clinical Use: | Color Doppler Ultrasound | Gross Weight: | 16kg |
---|---|---|---|
Probe: | 128 Array Element | Stardard Probe: | Convex Probe And Linear Probe |
Size: | 370mm * 355mm * 65mm | Beamformer: | 64 Channels |
High Light: | 128 Array Portable Ultrasound Scanners,Convex Probe Portable Ultrasound Scanners,3D Color Doppler Ultrasound Device |
Abdomen / Cardiac / Hearts/ Obstetrics / Gynecology / Fetal Cardiology / Transcranial Doppler / Small Parts / Vascular / Orthopedics
Physical Specifications
2 eSCI
3 eFCI
4 eView
5 eSpeed
Probes
LED Monitor
Size (Diagonal) | 15" |
Contrast Ratio | 800:1 |
Resolution | 1024×768 pixels |
Brightness | 230 cd/m2 |
Color Depth | 24bit |
Rotate Angle | ± 90° |
Grey Levels | 256 |
General Performance
Full Digital uwb Beamformer | 28672 channels |
Beam-former | Re-programmable |
Transmit Voltage | Adjustable (15 steps) |
Beam-former Frequency Range | 1~40 MHz |
The system has the advanced imaging technology and many unique features:
Holo Platform
Holo PW technology
• Max 3 sample gates simultaneous
• Allow to move each gate in real-time mode and frozen status.
• Used before, at & after vascular pathologic change position with synchronized one heart beat measurement.
• Holding breath becomes a history. With Holo PW, user can acquires several vessels at same time, such as renal artery and vein.
Spatial-Time Speckle Reduce Technology
• Noise movement trace is random
• Like Brown movement
• Based on the HOLO TM platform, system capture the noise with high frame rate
• Reduce the noise in the spatial and time two dimensions
Ultra-wide Accurate Steer imaging
• High performance probe with ultra-wide beaming
• Maximum steer angle for linear probe is 30°
• The minimum step size is 1°
• Accurate matching human blood vessels path
Obtaining more stronger Doppler signal, getting better spectrum and blood flow images
Extend FOV
B independent steering
• The steering can make the needle tip and needle path more clear
• B images also support ultra-wide angle accurate steering
FZoom function
After the normal measurement, you can name this application measurement item base on the value result. In daily clinical applications, it can help doctors to simplify the operation, to avoid duplication of measurements, to shorten the time of bed in next checking.
Movie dynamic storage
Complete recording operation process, adjust the depth, switch to the Color mode, you can provide a complete teaching demonstration video for anesthesia and so on
Most of competitors do no support such function
Contact Person: Peng
Tel: +86-13632708845
Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.
Factory Address:Block 1B, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.