Home ProductsSuperconducting MRI

18 KW Superconducting MRI Motor Driven 1.5 Tesla MRI Machine Bstar-150

18 KW Superconducting MRI Motor Driven 1.5 Tesla MRI Machine Bstar-150

  • 18 KW Superconducting MRI Motor Driven 1.5 Tesla MRI Machine Bstar-150
  • 18 KW Superconducting MRI Motor Driven 1.5 Tesla MRI Machine Bstar-150
18 KW Superconducting MRI Motor Driven 1.5 Tesla MRI Machine Bstar-150
Product Details:
Place of Origin: China
Brand Name: BASDA
Certification: CE, ISO13485
Model Number: Bstar-150
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: 1 unit/wooden box
Delivery Time: 30-45 Days
Payment Terms: Credit card, Paypal, T/T, Western Union, MoneyGram
Supply Ability: 200 Machines per Year
Contact Now
Detailed Product Description
Patient Table Driven Mode: Motor Driven Name Of MRI System: Superconducting MRI
Max RF Amplifier Power: 18 KW Power RF Receiving Amplifier Noise Level: Low
Bore Width: 600 Mm Coil Technology: AIT Coils
High Light:

Superconducting MRI 1.5 Tesla

,

AIT Coils Superconducting MRI

,

AIT Coils 1.5 Tesla MRI Machine

Superconducting MRI Machine Bstar-150 

 
Special Design about Large Bore 1.5T MRI Machine
  • With high accuracy diagnosis automatic bed design and intelligent speed control, it has greatly improved patient comfort as well as patient flow.
  • BASDA MRI design is inspired by sapphire, which is a transparent armor material for military vehicle. The hardness of sapphire is stronger than any other natural materials except diamond. It is a symbol of practical performance and sound quality.
  • Dual side operation panel, the operator can operate the system at both sides of the magnet, saves positioning time, and increases the daily patient flow.
  • The smart control screen mounted on the gantry, helps the operator to confirm the table position and patient status in real time, increasing the daily patient flow.
  • Golden-ratio design magnet. A long magnet will make the patient feel depressed during the examination while a short magnet will greatly decrease the homogeneity. The "golden-ratio" design magnet is the elegant balance between both.

18 KW Superconducting MRI Motor Driven 1.5 Tesla MRI Machine Bstar-150 0

 
Gradient sub system
 
Gradient sub system directly determines the spatial encoding of MRI system, it produces the signal information, at the same time it can perform GR series sequence scanning, it is the foundation of MRI system’s spatial resolution ability, gradient sub system also directly affect the scanning image thin slice scanning.
 
The linearity of gradient system of MRI system determine the accuracy of spatial location information, ensuring that in any acquisition, the image distortion is limited.
 
Gradient switching rate is an important factor of MRI scanning speed. Bstar-150 using the self-shielding gradient coil and high duty cycle gradient amplifier system, together with eddy elimination technology and design, can avoid the eddy current between the metal shielding layers, raise up the spatial encoding ability of the magnetic resonance signal and make the scan more precise, ensure high resolution image quality.
 
During superconducting MRI scans, the noise is much bigger than permanent MRI systems, and staying in a closed environment, the patient is easy to fall into tension. Bstar-150’s gradient sub system adopts special hardware noise reduction design technology, the gradient noise is reduced to 2/3, provide patients with friendly scanning environment.
 
The gradient system is equipped with automatic detection function, if the temperature is too high, the system can intelligently stop the scanning, to protection of hardware from being damaged.
 
The system use water chiller to produce a stable running condition.
 
RF sub system
 
The RF sub system is the source of MRI proton excitation energy, its efficiency directly affects the MRI relax signal. RF receiver receive MRI relax signal, a good receiving coil can improve the SNR of image.
 
The RF sub system is similar as highway lane, the more lanes, the faster flow of vehicles. Vice versa, the more the RF system channels, the faster parallel acquisition, thus the system can process the greater the amount of data in the same time, reduce the imaging time. Bstar-150 suing 8 / 16 channel radio frequency receiving, combined with the latest parallel sampling technology, using the DDC digital direct sampling, can short the scan time and get excellent image quality.
 
 
 
 
 
 

Interactive environment

1. Motor-driven patient table, 200kg weight capacity.

2. Built-in-magnet high resolution 8 inch screen, the operation is convenient.

3. Have emergency stop function, protect the patients.

4. High positioning accuracy.

5. Support operation on both sides of the magnet, convenient and quick.

 

Water chiller set

  • Intelligent touch screen design, visual operation, and be convenient for maintenance.
  • automatic overheating, leaking, fault detection, safe and reliable.
  • one key recovery function.
  • config with a set of spare water chilling unit, no need to have any worry about the system downtime.

 

E-alarm technology

 

At the same time, Bstar-150 has a special monitoring system which simple and easy to operate. It can real-time monitor the magnet internal pressure, temperature and liquid helium level. If the magnet condition is abnormal, the monitoring system can automatically send alarm information to the user's phone which can greatly reduce the risk of magnet quenches.

 
 
 
 
18 KW Superconducting MRI Motor Driven 1.5 Tesla MRI Machine Bstar-150 1
Our 1.5T MRI Bstar-150 installed at Berhampur, India.
 
 
Bstar-150 Software Description
 
Bstar-150 provides comprehensive scan kit and scanning sequence, with rich clinical application of the full body, with a full range of scan plan, assist the customer’s clinical diagnosis. Advanced scanning sequence are provided as well as all routine scan, the system also can take vascular imaging, includes a broad range of capabilities supporting fast, accurate diagnosis of brain conditions and injuries. From anatomical depiction to vascular 3D reconstruction.
 
Bstar-150 provides the power, coils and sequences for fast, intuitive, high quality spine imaging, from routine views to advanced stitching studies.
 
Bstar-150 provides a versatile suite of imaging capabilities for body imaging to meet the growing demands of abdominal, pelvic, and breast exams. Including MRU/MRCP/MRM imaging, and other advanced imaging sequences. Rich post-processing software can optimize images in case necessary to help in complex diseases diagnosis, excellent image quality and abundant imaging techniques.
 
Workflow is critical to the efficient operation of an MRI. It impacts patient satisfaction, image quality and cost effectiveness. Bstar-150 provides full preset of clinical diagnostic scan protocol, based on rich clinical experience, corresponding arrangement and optimization have been made per related clinical application features for the scan procedure and sequence parameters of the preset scan method. With unmatched clinical capability, Bstar-150 provides an unprecedented ability to acquire complete exams with a motion compensated scan technique.
 
The RF system, delivers integrated coil technology to simplify patient positioning and extend coverage with high SNR, providing extremely fast scan solution, with the help of brand-new multi-channel coil and parallel accelerating technique, it gives higher spatial resolution of head images, clearer display of anatomic structure and lesions, and less artifact.
For restless patients and those who can’t cooperate, the preset extremely fast scan sequence can be used, which is very appropriate for fetus, newborns and infants.
 
K_Rotat artifact erasing technique, by using stripped K space rotating filling method to complete acquisition, can completely erase the effect of movement artifact on images and greatly improve SNR at the same time to provide guarantee for accurate diagnosis.
High resolution isotropic diffusion imaging, based on powerful gradient system and amplifier system, Bstar-150 realizes faster and more reliable DWI images with high resolution, anatomic structure of head is clear, diffusion image features is obvious, very convenient for lesion location lock and lesion nature diagnosis.
 
HD susceptibility-weighted imaging, imaging based on the differences of magnetic susceptibility in different tissues, is a contrast enhancement technique which reflects magnetic properties of tissue. It is extremely sensitive to bleeding or deoxidation part in blood, can provide accurate information on bleeding, arteriovenous malformation, iron deposit to realize faster and more accurate diagnosis, even the very small lesion can be quickly diagnosed too.
 
By adopting the brand-new phase array coil and scan control software, application of parallel acquisition accelerating technique, improve most sequence scanning speed, on the premise of image quality guarantee, accelerating factor can reach 6 or more as the maximum. Bstar-150 system keeps pace with international design and research, keeps improving the present clinical functions to provide lifetime free software upgrade for its users as well as let the hospital enjoy the most advanced MRI clinical application techniques.
 
 
 

Contact Details
Shenzhen Basda Medical Apparatus Co., Ltd

Contact Person: Peng

Tel: +86-13632708845

Send your inquiry directly to us (0 / 3000)

Contact

Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.

Factory Address:Block 1B, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.