Place of Origin: | Shenzhen, China |
Brand Name: | BASDA |
Certification: | CE, ISO13485 |
Model Number: | Bstar-150 |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | 1 unit/wooden box |
Delivery Time: | 30-45 Days |
Payment Terms: | Credit card, Paypal, T/T, Western Union, MoneyGram |
Supply Ability: | 200 Machines per Year |
Gradient Cooling System: | Water Cooling Method | Shimming Method: | Active |
---|---|---|---|
Cold Head: | 4K | Magnet Height: | 600 Mm Height |
Max. Liquid Helium Full Filled: | 800 Liters | Shielding Room: | Yes |
High Light: | Superconducting 1.5 T Mri Machine,Superconducting Magnet 1.5 T Mri Machine,Automatic Table Superconducting Magnet Mri |
BASDA superconductive MRI Bstar-150 is the one which breaks the technology monopoly by foreign companies, a new generation of superconductive MRI that based on rich research and development and clinical experience, is applicable to all parts of the body, fully meet the central nervous system, abdominal, pelvic cavity and etc.
Short bore design, superconductive magnet system with zero consumption of liquid helium, equipped with a new generation of the digital multi-channel spectrometer, high performance of the gradient system, intelligent recognition function of the coils, user-friendly software, which including an industrial special computer system, various general applications and advanced practical applications.
This system is equipped with sophisticated imaging sequences and techniques, which can provide the perfect conventional imaging and rich advanced functional imaging.
Operating software uses an independently developed system, doctors can easily and quickly register patients, browse images, advanced post-processing, external device connectivity, and other functions.
1.5T Superconducting MRI Software
BASDA superconductive MRI Bstar-150 is the one which breaks the technology monopoly by foreign companies, a new generation of superconductive MRI that based on rich research and development and clinical experience, is applicable to all parts of the body, fully meet the central nervous system, abdominal, pelvic cavity and etc.
This system is equipped with sophisticated imaging sequences and techniques, which can provide the perfect conventional imaging and rich advanced functional imaging.
Operating software uses an independently developed system, doctors can easily and quickly register patients, browse images, advanced post-processing, external device connectivity, and other functions.
Short bore design, superconductive magnet system with zero consumption of liquid helium, equipped with a new generation of the digital multi-channel spectrometer, high performance of the gradient system, intelligent recognition function of the coils, user-friendly software, which including an industrial special computer system, various general applications and advanced practical applications.
1.5T Superconducting MRI Configuration
No. | Item | Specification |
1 | Magnet System | |
1.1 | Magnet Type | Superconducting |
1.2 | Field Strength | 1.5T |
1.3 | Shielding Method | Active |
1.4 | Shimming Method and Type | Active + Passive + Dynamic |
1.5 | Magnet stability | ≤0.1ppm/h |
1.6 | Homogeneity (DSV, VRMS) | |
1.6.1 | 45cm | ≤0.832ppm |
1.6.2 | 40cm | ≤0.323ppm |
1.6.3 | 30cm | ≤0.107ppm |
1.6.4 | 20cm | ≤0.041ppm |
1.6.5 | 10cm | ≤0.01ppm |
1.7 | Length of magnet(exclude cover) | 157cm |
1.8 | Inner diameter of magnet | 600mm |
1.9 | 5 Gauss fringe field(X,Y,Z axis) | ≤2.5m x 2.5m x 4.0m |
1.10 | Total capacity of liquid helium (100% liquid helium full filled) | 800L |
1.11 | Filling liquid helium period | ≥4 Years |
1.12 | Liquid helium “zero”consumption technology | Yes |
2 | Gradient System | |
2.1 | Maximum gradient field (single axis, invalid) | 41mT/m |
2.2 | Maximum gradient slew rate(single axis, invalid) | 187mT/m/ms |
2.3 | Minimum gradient rise time | 0.22ms |
2.4 | Maximum gradient field and slew rate reached at the same time | Yes |
2.5 | Gradient cooling system | Water cooling |
2.6 | Full digital real-time transmit and receiving gradient control system | Yes |
3 | RF System | |
3.1 | Max RF amplifier power | 18kW |
3.2 | Center frequency | 63.87MHz |
3.3 | Real-time digital RF energy monitoring | Yes |
3.4 | Real-time digital RF short-term accumulation monitoring | Yes |
3.5 | Real-time digital RF long-term accumulation monitoring | Yes |
3.6 | Parallel working RF receiver channels | 8/16 |
3.7 | Parallel working RF A/D converters | 8/16 |
3.8 | Each coil unit has corresponding pre-amplifier | Yes |
3.9 | Parallel acquisition technology platform | Yes |
3.10 | Maximum bandwidth of each parallel acquisition receive channels | ≥1.0MHz |
3.11 | Transmission bandwidth | 550kHz |
3.12 | Maximum receiver signal resolution | ≥16bit |
3.13 | Fully digital RF system | Yes |
3.14 | RF receiving amplifier noise level | ≤0.45dB |
3.15 | Multi-channel phased array receiver coil | |
3.15.1 | Head coil | Available |
3.15.2 | Neck coil | Available |
3.15.3 | Body coil | Available |
3.15.4 | Knee coil | Available |
3.15.5 | Shoulder coil | Available |
3.15.6 | Ankle coil | Available |
3.15.7 | Wrist coil | Available |
3.15.8 | Breast coil | Available |
Remark: The coil configuration is subject to the final contract | ||
4 | Scan environment | |
4.1 | Patient table driven mode | Motor-driven |
4.2 | Position accuracy | ≤0.5mm |
4.3 | Table length | 2400mm |
4.4 | Horizontal movement range | 2055mm |
4.5 | Horizontal motion maximum speed | ≥200mm/s |
4.6 | Patient table lowest height | 675mm |
4.7 | Maximum patient weight | 200kg |
4.8 | Feet-first entry mode | Yes |
4.9 | Table can be controlled by machine cover in case of emergency | Yes |
4.10 | Table control system on both side of rack | Yes |
4.11 | Lighting, ventilation, call system | Be able to adjust |
5 | Computer system | |
5.1 | MRI software | BASDA |
5.2 | System software | WINDOWS 7 |
5.3 | CPU | ≥3.1GHz |
5.4 | Main memory | ≥4GB |
5.5 | Hard disk | ≥500GB |
5.6 | Color LCD monitor | 24” |
5.7 | Monitor resolution | 1920×1200 |
5.8 | External storage | DVD/USB |
5.9 | DICOM3.0 | Yes |
6 | Scanning parameter | |
6.1 | Spin-echo sequence | Yes |
6.1.1 | SE 2D/3D | Yes |
6.1.2 | FSE 2D/3D | Yes |
6.1.3 | FSE sharing | Yes |
6.1.4 | Single shot FSE | Yes |
6.1.5 | Spin echo fat-suppression imaging | Yes |
6.1.6 | Spin echo frequency fat suppression imaging | Yes |
6.1.7 | Spin echo water suppression imaging | Yes |
6.2 | GRE 2D/3D | Yes |
6.3 | DWI | Yes |
6.3.1 | Max. b value | 10000 |
6.4 | IR sequence | Yes |
6.4.1 | IR | Yes |
6.4.2 | FIR(water / fat suppression) | Yes |
6.4.3 | FLAIR | Yes |
6.4.4 | STIR | Yes |
6.4.5 | Water-fat Separation | Yes |
6.5.1 | Pre-saturation | Yes |
6.6 | Gating | Yes |
6.7 | Accelerated sequence | Yes |
6.8 | Anti-movement scanning technology | Yes |
6.9 | Min. 2D thickness | 0.1mm |
6.10 | Min. 3D thickness | 0.05mm |
6.11 | Max. FOV | 50cm |
6.12 | Min. FOV | 1cm |
7 | Advanced imaging technology | |
7.1 | Body Imaging | Yes |
7.1.1 | Ultra-fast imaging technology | Yes |
7.1.2 | Phase / de-phase imaging technology | Yes |
7.1.3 | MR cholangiopan-creatography (MRCP) | Yes |
7.1.4 | MR urography (MRU) | Yes |
7.1.5 | MR Myelography (MRM) | Yes |
7.2 | Neuro imaging | Yes |
7.3 | Diffusion weighted imaging set | Yes |
7.3.1 | Isotropic acquisition | Yes |
7.3.2 | ADC measurement | Yes |
7.4 | MR angiography(MRA) | Yes |
7.4.1 | 2D/3D TOF technology | Yes |
7.4.2 | Continuous multi-layer 3D TOF technology | Yes |
7.4.3 | Contrast enhanced MRA | Yes |
7.4.4 | Magnetization transfer (MTC) | Yes |
7.4.5 | Maximum intensity projection | Yes |
7.5 | Susceptibility weighted imaging (SWI) | Yes |
7.6 | Parallel acquisition technology | Yes |
7.6.1 | Algorithm based on image | Yes |
7.6.2 | Algorithm based on K-space | Yes |
7.6.3 | Max. parallel acquisition acceleration factor | 4 |
7.6.4 | Automatic calibration technology | Yes |
7.6.5 | Applied direction of parallel acquisition factor | X,Y,Z |
7.7 | Artifact correction technology | Yes |
7.7.1 | Fluid compensation | Yes |
7.7.2 | Respiratory compensation | Yes |
7.7.3 | Head motion artifact correction | Yes |
7.7.4 | Elimination of magnetic sensitive artifact | Yes |
7.7.5 | Eddy current adaptive correction | Yes |
7.7.6 | Gradient linearity correction | Yes |
7.7.7 | Multi-echo phase correction | Yes |
7.8 | Rapid automatic correction technology | Yes |
7.9 | Automatic frequency tracking technology | Yes |
7.10 | Automatic coil recognition technology | Yes |
7.11 | Automatic phase correction technology | Yes |
7.12 | Echo navigation technology | Yes |
7.13 | RF balance drive technology | Yes |
7.14 | RF de-phase technology | Yes |
7.15 | Gradient de-phase technology | Yes |
7.16 | Section scanning technology | Yes |
Contact Person: Peng
Tel: +86-13632708845
Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.
Factory Address:Block 1B, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.