Home ProductsPatient Monitoring Machine

50mm/S Sweep 350bpm Alarm Patient Monitoring Machine 12in TFT Handheld

50mm/S Sweep 350bpm Alarm Patient Monitoring Machine 12in TFT Handheld

  • 50mm/S Sweep 350bpm Alarm Patient Monitoring Machine 12in TFT Handheld
50mm/S Sweep 350bpm Alarm Patient Monitoring Machine 12in TFT Handheld
Product Details:
Place of Origin: Guangdong, P.R.C.
Brand Name: Basda Medical
Certification: CE, ISO
Model Number: BMP-9000JA
Payment & Shipping Terms:
Minimum Order Quantity: 10
Price: Negotiable
Packaging Details: 1 unit/carton, 370*210*430mm
Delivery Time: Various by Logistics and Custom
Payment Terms: Credit card, Paypal, T/T, Western Union, MoneyGram
Supply Ability: 3 Days per 10 Units
Contact Now
Detailed Product Description
Screen: 12" Inch TFT Screen Name: Black And White Patient Monitor
Size: 370 X 210 X 430mm Gross Weight: 5.5 Kilogram
Battery: Built-in Rechargeable Lithium Battery Waveforms: 7-lead ECG
Cetificate: CE Safety Level: Class I, Type CF
High Light:

50mm/S Sweep Patient Monitoring Machine

,

350bpm Alarm Patient Monitoring Machine

,

12in TFT Handheld Patient Monitor

 
 
Features:
 

 

 
 
Specifications
 

Parameters Technical Specifications
ECG

Lead mode: 5 –lead(R,L,F,N,C)
Lead selection : I, II, III, avR, avL, avF, V
Waveform: 3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 12.5mm/s;25mm/s;50mm/s
Heart rate range: Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichecer is greater
Resolution: 1bpm
Filter: surgery mode:1~20Hz

monitor model:0.5~40Hz

Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%

Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detection:
Measurement range: 2.0mV~+2.0mV
 
Alarm Range: -2.0mV~ +2.0mV
Accuracy: -0.8mV ~+0.8Mv
Error: +0.02Mv

Respiration
 

Method: Thoracic impedance
Measurement range: Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm: YES,10~40s
Resolution: 1rpm
Accuracy: +2rpm

FHR

Transducer: Multi-crystal, Pulsed Doppler
Measurement range: 50~210 BPM
Working frequency: 1 MHz
Strength: <5mW/cm2
Signal processing:
special DSP system and modern recognization.
Resolution: 1BPM
Accuracy: ±1BPM
Alarm Range: High: 160,170,180,190 BPM,
Low: 100,110,120 BPM

TOCO Measuring

Manual button marking,
automatic FM identifying function

EtCO2 (Sidestream CO2)

Measurement range: 0~99mmHg
Accuracy: +2mmHg (0~40mmHg)
Sampling Range: 100ml/min
Sampling rate accuracy: 15%
Respiration rate: 0~120rmp
Respiration accuracy: +2rmp (0~70rmp)
+5rmp (>70rmp)
Respiration time: <240msec (10% to 90%)
Delay time: <2s

EtCO2 (Mainstream CO2)

Method: Infrared Spectrum
Range: 0.0-10% (0~76%)
Resolution: 1mmHg (0.1%)
Accuracy: <5%(±4.0 mmHg)
Or<10%(of Readings)

Recorder

Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type: Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record

Scan Speed for ECG Waveform is adjustable 12.5mm/s accuracy ±10%
25mm/s accuracy±10%
50mm/s accuracy±10%
NIBP

Method: Digital Automatic oscillometric
Operation mode : Manual/Automatic/continuous
Auto measurement time: Adjustable(1~480min)
Measurement Unit: mmHg/Kpa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range:
Range of Systolic pressure: Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure: Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure: Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection: Double safety protection
Resolution: 1 mmHg
Alarm: Systolic, Diastolic, Mean

Resolution Pressure 1mmHg
Cuff Pressure ±3 mmHg
Accuracy ±10% or ±8mmHg, which is greater
Over-pressure Protection:
Adult Mode 315±10 mmHg
Pediatric Mode 265±10 mmHg
Neonatal Mode 155±10 mmHg
SPO2

Measurement range: 0~100%
Resolution: 1%
Accuracy: +2%(70-100%);0-69% unspecified
Arrhythmia analysis: YES
Alarm range 0~100%
Pulse Rate: range: 20~300bpm
Resolution: 1bpm
Error: +1bpm or +2%,whichever is greater

Pulse Rate(PR) Measuring and Alarm Range 0~250bpm
Resolution 1bpm
Measuring Accuracy ±2bpm or ±2%, which is greater
Alarm Accuracy ±2bpm
TEMPERATURE

Compatible probe: YSI or CYF
Measurement range: 5~50℃
Resolution : 0.1℃
Accuracy: +0.1℃
Refreshing time: about 1
Average measuring time: <10s

IBP

Channel: 2 channels
Range: -50-300mmHg
Resolution: 1mmHg
Accuracy: ±4mmHg(±4%)
Unit: mmHg, Kpa
Converter Sensitivity: 5mV/V/mmHg
Transducer sites: ART/PA/CVP/LAP/RAP/ICP

 
 
 
Accessories:
 
 
1. Reusable ECG Leadwires----1 set

2. LNOP Reusable SpO2 Sensor----1 set

3. NIBP Hose----1 set

4. Chest electrode (10pcs/set)

5. Temperature Trunk Cables----1 set

6. 5 Lead ECG Electrodes----1 set

7. Power Cord----1 set

9. Grounding Cable----1 set

10. ECG Recording Paper----1 set

11. D-lite++ Patient Spirometry Sets----Optional

 

 

Contact Details
Shenzhen Basda Medical Apparatus Co., Ltd

Contact Person: Peng

Tel: +86-13632708845

Send your inquiry directly to us (0 / 3000)

Contact

Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.

Factory Address:Block 1B, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.