Place of Origin: | Guangdong, P.R.C. |
Brand Name: | Basda Medical |
Certification: | CE, ISO |
Model Number: | BMP-9000JA |
Minimum Order Quantity: | 10 |
---|---|
Price: | Negotiable |
Packaging Details: | 1 unit/carton, 370*210*430mm |
Delivery Time: | Various by Logistics and Custom |
Payment Terms: | Credit card, Paypal, T/T, Western Union, MoneyGram |
Supply Ability: | 3 Days per 10 Units |
Display: | 12" Color TFT Screen TFT | Parameters: | SpO2(F-5), NIBP, 5 Lead ECG, TEMP, RESP, PR, HR |
---|---|---|---|
Product Name: | Vital Sign Patient Monitor | After-sales Support: | Online Technical Support |
Weight: | 5.5 Kg | Lead Mode: | 5-lead (R,L,F,N,C) |
High Light: | NIBP TEMP Patient Monitoring Equipment,12.5mm/S Patient Monitoring Equipment,1bpm Portable Patient Monitor |
Standard parameters:
5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional:
Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,
Specifications
Parameters | Technical Specifications |
ECG | Lead mode: 5 –lead(R,L,F,N,C) monitor model:0.5~40Hz Diagnostic mode:0.05~130Hz Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
Respiration | Method: Thoracic impedance |
FHR | Transducer: Multi-crystal, Pulsed Doppler |
TOCO Measuring | Manual button marking, |
EtCO2 (Sidestream CO2) | Measurement range: 0~99mmHg |
EtCO2 (Mainstream CO2) | Method: Infrared Spectrum |
Recorder | Build-in, thermal array |
Scan Speed for ECG Waveform is adjustable | 12.5mm/s accuracy ±10% 25mm/s accuracy±10% 50mm/s accuracy±10% |
NIBP | Method: Digital Automatic oscillometric |
Resolution | Pressure 1mmHg Cuff Pressure ±3 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg |
SPO2 | Measurement range: 0~100% |
Pulse Rate(PR) | Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm |
TEMPERATURE | Compatible probe: YSI or CYF |
IBP | Channel: 2 channels |
Performance Specifications
Display | 12.1”color TFT |
Trend | Parameter graphic and tabular trends: |
Storage | NIBP: 1000 groups |
Battery | Rechargeable lead acid cell, 12v/4AH |
Alarm | User-adjustable High, Medium and Low limits 3-level |
Indicator | Power/battery indicator light |
Networking | Connected to central monitoring system |
Trace | 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) |
Recorder | Build-in, thermal array |
Recording type | Frozen waveform record |
What is in the box?
(1) 5 lead ECG cable
(2) 1 spo2 probes
(3) 1 NIBP probe
(4) 1 temp probe
(5)1 ground connecting liner
(6) Chest electrode (10pcs/set)
Contact Person: Peng
Tel: +86-13632708845
Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.