Product: | Black And White 12.1 Inch Monitor | Parameters: | 5 Lead ECG, SpO2(F-5), NIBP, TEMP, RESP, PR, HR |
---|---|---|---|
Other Name: | Vital Sign Monitor | Waveforms Display In Phase: | 7-lead ECG |
Lead Mode: | 5-lead (R, L, F, N, C) | Recorder: | Build-in, Thermal Array |
High Light: | 350bpm Alarm Patient Monitoring Machine,12.1 Inch Patient Monitoring Machine,50mm/S Printing Medical Monitoring Device |
Standard parameters:
1. 12.1” color TFT display, high resolution: 800×600dpi;
2. Separated para board: ECG, NIBP, SpO2 board;
3. Full touch-screen enables intuitive operation by clicking on the specific parameters or the waveform in real-time, standard configuration includes the navigation knob.
4. Real-time S-T segment analysis, and ARR analysis;
5. SpO2 Pitch Tone Variation and Drug Dose Calculation;
6. Parameter waveform and characters color selectable
7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
8. Networking capacity and TCP/IP networking platform enable abundant future upgrade
9. Time delay switch-off function keep the monitor data restart monitor;
10. Complete and flexible mounting solution for transportation and in-patient monitoring
Specifications
Parameters |
Technical Specifications |
ECG |
Lead mode: 5 –lead(R,L,F,N,C) Lead selection : I, II, III, avR, avL, avF, V Waveform: 3 and 7 channel selectable Gain selection: 0.5mm/mv,1mm/mv,2mm/mv Sweep speed: 12.5mm/s;25mm/s;50mm/s Heart rate range: Adult: 15~300bpm; Neonate/pediatric:15~350bpm Accuracy: +1bpm or +1%,whichecer is greater Resolution: 1bpm Filter: surgery mode:1~20Hz monitor model:0.5~40Hz Diagnostic mode:0.05~130Hz Scaling signal: 1mv,+3% Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range: 15~350bpm S-T segment detection: Measurement range: 2.0mV~+2.0mV
Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv Error: +0.02Mv |
Respiration |
Method: Thoracic impedance Measurement range: Adult:7~120rpm; Neonate/Pediatric:7~150rpm Apnea alarm: YES,10~40s Resolution: 1rpm Accuracy: +2rpm |
FHR |
Transducer: Multi-crystal, Pulsed Doppler Measurement range: 50~210 BPM Working frequency: 1 MHz Strength: <5mW/cm2 Signal processing: special DSP system and modern recognization. Resolution: 1BPM Accuracy: ±1BPM Alarm Range: High: 160,170,180,190 BPM, Low: 100,110,120 BPM |
TOCO Measuring |
Manual button marking, automatic FM identifying function |
EtCO2 (Sidestream CO2) |
Measurement range: 0~99mmHg Accuracy: +2mmHg (0~40mmHg) Sampling Range: 100ml/min Sampling rate accuracy: 15% Respiration rate: 0~120rmp Respiration accuracy: +2rmp (0~70rmp) +5rmp (>70rmp) Respiration time: <240msec (10% to 90%) Delay time: <2s |
EtCO2 (Mainstream CO2) |
Method: Infrared Spectrum Range: 0.0-10% (0~76%) Resolution: 1mmHg (0.1%) Accuracy: <5%(±4.0 mmHg) Or<10%(of Readings) |
Recorder |
Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined Recording width: 50mm Printing speed: 50mm/s Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |
Scan Speed for ECG Waveform is adjustable | 12.5mm/s accuracy ±10% 25mm/s accuracy±10% 50mm/s accuracy±10% |
NIBP |
Method: Digital Automatic oscillometric Operation mode : Manual/Automatic/continuous Auto measurement time: Adjustable(1~480min) Measurement Unit: mmHg/Kpa selectable Measurement types: Systolic, Diastolic, Mean Measurement range: Range of Systolic pressure: Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate :10~100mmHg Over-pressure protection: Double safety protection Resolution: 1 mmHg Alarm: Systolic, Diastolic, Mean |
Resolution | Pressure 1mmHg Cuff Pressure ±3 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg |
SPO2 |
Measurement range: 0~100% Resolution: 1% Accuracy: +2%(70-100%);0-69% unspecified Arrhythmia analysis: YES Alarm range 0~100% Pulse Rate: range: 20~300bpm Resolution: 1bpm Error: +1bpm or +2%,whichever is greater |
Pulse Rate(PR) | Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm |
TEMPERATURE |
Compatible probe: YSI or CYF Measurement range: 5~50℃ Resolution : 0.1℃ Accuracy: +0.1℃ Refreshing time: about 1 Average measuring time: <10s |
IBP |
Channel: 2 channels Range: -50-300mmHg Resolution: 1mmHg Accuracy: ±4mmHg(±4%) Unit: mmHg, Kpa Converter Sensitivity: 5mV/V/mmHg Transducer sites: ART/PA/CVP/LAP/RAP/ICP |
Accessories:
(1) 5 lead ECG cable
(2) 1 spo2 probes
(3) 1 NIBP probe
(4) 1 temp probe
(5)1 ground connecting liner
(6) Chest electrode (10pcs/set)