Place of Origin: | Guangdong, P.R.C. |
Brand Name: | Basda Medical |
Certification: | CE, ISO13485 |
Model Number: | BTI-030 |
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | 1 unit/wooden box |
Delivery Time: | 30-45 Days |
Payment Terms: | Credit card, Paypal, T/T, Western Union, MoneyGram |
Supply Ability: | 200 Machines per Year |
Shape: | Open Shape MRI | Material: | High Grade Nd-Fe-B Magnet |
---|---|---|---|
Field Stength: | 0.3T | Spectrometer: | Fully Digital |
Highlight: | Cost Effective | Max. Patient Weight Load: | 200kg |
High Light: | 200kg Load Permanent Magnet MRI Machine,CE 0.3T Permanent Magnet MRI Machine,200kg Load modern mri machine |
BASDA launched BTI-030 permanent MRI system in the year 2004, since then BASDA attracted many high-tech talents researched and developed this MRI product with our self-independent intellectual property. BTI-030 combined many pioneering MRI imaging technology and human based humanized design concept, make it achieving high. BTI-030 lead a technical revolution in the permanent MRI field.
BTI-030 permanent MRI system, not only had accumulated the products’ technical essence from major companies home and abroad, but also followed the developing trend, and with constant innovation, breakthrough in the industry field and achieved:
4D shimming:
Use of advanced active shimming algorithm for real-time automatic shimming on each examination to ensure the magnetic field always maintain the highest uniformity. Magnetic field homogeneity and stability of the MRI images always are the most important guarantee of the high-resolution, high SNR and high contrast. They are the important indicators of the level of magnet design, the better the smaller the value, directly determines the SNR of the image, like a car chassis, stability is essential, the magnetic field uniformity is maintained at <2.5ppm in 40cm the DSV Vrms, the system can complete a wide range of scanning (40cm).
Eddy Zero Technology:
Implementation of precision eddy current compensation algorithm, completely eliminate the impact of eddy current
The eddy current because of the high gradient and high slew rate come from ultra-fast sequence was resolved completely, which guarantee to get the best clinic image.
Advanced RF system
Fast 4 channels RF system
All phased array coils provide best SNR pictures.
BTI-035 @ Irbid, Jordan
Parameters for BTI-030 Permanent MRI System
No. | Item | Specification |
1 | Magnet System | |
1.1 | Magnet Type | Permanent magnet with automatic constant temperature system |
1.2 | Field strength | 0.30T |
1.3 | Magnet shape | C-shape |
1.4 | Homogeneity (40cm, DSV, VRMS) | ≤2.5ppm |
1.5 | Shim method | Active/Passive/Dynamic |
1.6 | Magnet vertical gap | 40cm |
1.7 | Accessibility (Horizontal opening angle) | >270° |
1.8 | 5 Gauss fringe field | 2.5m*2.5m*2.5m |
2 | Gradient System | |
2.1 | Gradient field strength (Single Axis) | 25mT/m |
2.2 | Gradient slew rate (Single Axis) | 75mT/m/ms |
2.3 | Rise time | 0.3ms |
2.4 | Gradient cooling system(Gradient coils and power electronics) | Air |
3 | RF System | |
3.1 | Spectrometer | Fully digital |
3.2 | RF system type | Digital Transmit and Receive |
3.3 | Number of RF channel | 4 |
3.4 | Transmitter amplifier peak power | 6kW |
3.5 | RF bandwidth of receiver | Each 400KHz |
3.6 | Dynamic range | ≥80dB |
3.7 | Noise factor | 0.3dB |
3.8 | Coil type | Phase array |
3.9 | Head coil | Available |
3.10 | Neck coil | Available |
3.11 | Body coil (small) | Available |
3.12 | Body coil (large) | Available |
3.13 | Knee coil | Available |
3.14 | Ankle coil | Available |
3.15 | Shoulder coil | Available |
3.16 | Soft coil | Available |
3.17 | Breast coil | Available |
3.18 | Wrist coil | Available |
Remark: The coil configuration is subject to the final contract | ||
4 | Patient communication | |
4.1 | Max. patient weight | 200Kg |
4.2 | High accurate position assist | Yes |
4.3 | Localizer | Yes |
4.4 | Position accurate | ≤1mm |
4.5 | Position accessories | Yes |
4.6 | Emergence call | Yes |
4.7 | Communication system | Yes |
5 | Computer system | |
5.1 | Host computer | Dual core |
5.2 | System software | BASDA |
5.3 | OS | WINDOWS 7 |
5.4 | CPU clock rate | ≥2.8GHz, be able for extension |
5.5 | Main memory | ≥2GB, be able for extension |
5.6 | Color LCD monitor | 24” |
5.7 | Keyboard and mouse | Standard |
5.8 | Hard disk | ≥250GB, be able for extension |
5.9 | Media driver | CRW / DVD |
5.10 | DICOM 3.0 | Yes |
5.11 | Ethernet | Yes |
6 | Scanning parameter | |
6.1 | Max. FOV | 400mm |
6.2 | Min. FOV | 20mm |
6.3 | Min. 2D Thickness | 1mm |
6.4 | Min. 3D thickness | 0.1mm |
6.5 | Max. Image matrix | 1024*1024 |
7 | Scanning sequence &imaging technology | |
7.1 | Spin echo 2D/3D (SE 2D/3D) | Yes |
7.2 | Multi-slice multi-echo(MSME) | Yes |
7.3 | Gradient echo(GRE 2D/3D) | Yes |
7.4 | Steady state process gradient echo( SSPGRE) | Yes |
7.5 | Fast spin echo (FSE) | Yes |
7.6 | Fast double echo(FDE) | Yes |
7.7 | Fast recover fast spin echo(FRFSE) | Yes |
7.8 | Single shot fast spin echo(SSFSE) | Yes |
7.9 | Multi shot fast spin echo (MSFSE) | Yes |
7.10 | Inversion recovery (IR) | Yes |
7.11 | Inversion recovery fast spin echo (IRFSE) | Yes |
7.12 | Short time inversion recovery (STIR) | Yes |
7.13 | Fluid attenuated inversion recovery (FLAIR) | Yes |
7.14 | Gating technology | Yes |
7.15 | Breath holding scan | Yes |
7.16 | TOF 2D MRA | Yes |
7.17 | TOF 3D MRA | Yes |
7.18 | Diffusion weighted imaging (DWI) | Yes |
7.19 | Max. b Value | 1000s/mm2 |
7.20 | Magnetization transfer (MTC) technology | Yes |
7.21 | MIP | Yes |
7.22 | MinIP | Yes |
7.23 | 3D position | Yes |
7.24 | Pre-saturation technology (PS) | Yes |
7.25 | Pre-saturation adjustment technology | Yes |
7.26 | Part metal implant scan technology | Yes |
7.27 | Automatic coil tuning | Yes |
7.28 | MRM | Yes |
7.29 | MRU | Yes |
7.30 | MRCP | Yes |
7.31 | Online image filtration | Yes |
7.32 | Online post procession | Yes |
7.33 | Optimal algorithm of active shimming | Yes |
7.34 | Scan sequence queuing | Yes |
7.35 | Multi-layer and multi-angle scanning technology | Yes |
7.36 | Optimize bandwidth acquisition technology | Yes |
7.37 | Flow compensation | Yes |
7.38 | Parallel acquisition technology | Yes |
7.39 | Section acquisition technology | Yes |
7.40 | Scan parameter preset | Yes |
7.41 | Oversampling technology | Yes |
7.42 | Image fusion technology | Yes |
7.43 | Artifact suppression technology (K_Rotat) | Yes |
7.44 | Thin imaging technology | Yes |
7.45 | Movie playback technology | Yes |
7.46 | Post processing package | Yes |
Standard Configurations | Unit | Quantity |
Standard Hardware include: | ||
RF shielding room | set | 1 |
Permanent Nd-Fe-B magnet, Full open C-shaped eddy current-free self-consistent temperature magnet 0.35T | set | 1 |
Spectrometer | pc | 1 |
Preamplifier | set | 1 |
RF amplifier | pc | 1 |
Flat panel transmitter coil | set | 1 |
Gradient amplifier | pc | 1 |
Gradient coil | set | 1 |
Computer | set | 1 |
Imaging monitor | set | 1 |
Operation table | set | 1 |
Cover and diagnostic bed | set | 1 |
Head coil | set | 1 |
Neck coil | set | 1 |
Small body coil | set | 1 |
Large body coil | set | 1 |
Knee coil | set | 1 |
bed pats | set | 1 |
Quality control water phantom | pc | 1 |
MRI safety marks | set | 1 |
Technical manual | pc | 1 |
User manual | pc | 1 |
Maintenance manual | pc | 1 |
3-phase AC voltage stabilizer | pc | 1 |
Magnet self-consistent temperature system | set | 1 |
Dual-voice-communication system | set | 1 |
Patient bed laser location system | set | 1 |
Standard Software include | ||
Imaging software | set | 1 |
Pulse sequence | set | 1 |
Imaging enhancement software | set | 1 |
DICOM interface software | set | 1 |
Cardiovascular imaging software | set | 1 |
Diffusion functional imaging system package | set | 1 |
(MR CINE)/ MR CINE | set | 1 |
Accident analyzing software | set | 1 |
Quality control software | ||
Optional Modules | Unit | |
Shoulder coil | set | |
Sport joint coil | set | |
Wrist Coil | set | |
Breast Coil | set | |
Flexible coil | set | |
Flexible body coil | set | |
Flat spine coil | set | |
Remark: RF shielding room are including RF shielding room decoration, RF shielding door, observation window, transmission board, Waveguide plate, interior lighting; excluding room construction and flooring, outside decoration of RF shielding room, operation room, equipment room, air-conditioner room and air-conditioner, external electric access and independent ground lead. | ||
Basda will provide the technical staff for installation, including RF shielding room installation, MRI system installation, and training; The buyer shall bear round trip air ticket from China to installation country, local transportation, food and board of Basda's technicians in country of installation for the purpose of installation, training and service. | ||
Contents are subject to change without prior notice |
Contact Person: Peng
Tel: +86-13632708845
Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.
Factory Address:Block 1B, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.