BTI-042 combined many pioneering MRI imaging technology and human based humanized design concept, make it achieving high, lead a technical revolution in the permanent MRI field.
BTI-042 permanent MRI system, not only has accumulated technical essence from famous suppliers, but also followed the developing trend, and with constant innovation, breakthrough in the industry field and achieved:
Eddy zero technology
Make sure the imaging quality achieved qualitative improve.
The shimming algorithm technology (ensure field strength with high uniformity and stability), ensure the MRI system operating stably with high quality and high performance.
The high magnetic uniformity, high stability, fast and accurate position operation are always the hard breakthrough technical bottleneck. BTI-042 permanent MRI system not only breakthrough the bottleneck historically, and achieved the “high stability, high performance, high imaging quality and high efficiency”. And with the special designed high power gradient magnet field for BTI-042, it achieved as an all-new concept permanent MRI system.
Much open and comfort
More patient comfort and more space for surgery. Affinity C-shape magnets, creating a maximum of openness, offer a maximum vision for patients, especially leave much space comfort for obese patients, minimizing claustrophobia of patients and providing more space for MR intervention surgery.
Very good gradient system
Gradient system helps to provide higher resolution pictures, BTI-042 gradient system(X,Y,Z) gradient intensity is 25mT/m,Higher the gradient intensity, faster imaging speed, shorter of scanning time; Higher the gradient intensity, thinner of imaging slice, higher of image resolution
The new technology
4D shimming:
Use of advanced active shimming algorithm for real-time automatic shimming on each examination to ensure the magnetic field always maintain the highest uniformity. Magnetic field homogeneity and stability of the MRI images always are the most important guarantee of the high-resolution, high SNR and high contrast. They are the important indicators of the level of magnet design, the better the smaller the value, directly determines the SNR of the image, like a car chassis, stability is essential, the magnetic field uniformity is maintained at <2.5ppm in 40cm the DSV Vrms, the system can complete a wide range of scanning (40cm).
Eddy Zero Technology:
a) Magnet design uses breakthrough anti-eddy current technology
b) The gradient coil using self-shielded active anti - eddy current technology
c) Implementation of precision eddy current compensation algorithm, completely eliminate the impact of eddy current
The eddy current because of the high gradient and high slew rate come from ultra-fast sequence was resolved completely, which guarantee to get the best clinic image.
Advanced RF system
Fast 4 channels RF system
All phased array coils provide best SNR pictures.
3. BTI-042 Specification
No. Item Specification
1 Magnet System
1.1 Magnet Type Permanent magnet with automatic constant temperature system
1.2 Field strength 0.42T
1.3 Magnet shape C-shape
1.4 Homogeneity (40cm, DSV, VRMS) ≤2.5ppm
1.5 Shim method Active/Passive/Dynamic
1.6 Magnet vertical gap 40cm
1.7 Accessibility (Horizontal opening angle) >250°
1.8 5 Gauss fringe field 2.5m*2.5m*2.5m
2 Gradient System
2.1 Gradient field strength (Single Axis) 25mT/m
2.2 Gradient slew rate (Single Axis) 75mT/m/ms
2.3 Rise time 0.3ms
2.4 Gradient cooling system(Gradient coils and power electronics) Air
3 RF System
3.1 Spectrometer Fully digital
3.2 RF system type Digital Transmit and Receive
3.3 Number of RF channel 4
3.4 Transmitter amplifier peak power 5kW
3.5 RF bandwidth of receiver Each 400KHz
3.6 Dynamic range ≥80dB
3.7 Noise factor 0.3dB
3.8 Coil type Phase array
3.9 Head coil Available
3.10 Neck coil Available
3.11 Body coil (small) Available
3.12 Body coil (large) Available
3.13 Knee coil Available
3.14 Ankle coil Available
3.15 Shoulder coil Available
3.16 Soft coil Available
3.17 Breast coil Available
3.18 Wrist coil Available
Remark: The coil configuration is subject to the final contract
4 Patient communication
4.1 Max. patient weight 200Kg
4.2 High accurate position assist Yes
4.3 Localizer Yes
4.4 Position accurate ≤1mm
4.5 Position accessories Yes
4.6 Emergence call Yes
4.7 Communication system Yes
5 Computer system
5.1 Host computer Dual core
5.2 System software BASDA
5.3 OS WINDOWS 7
5.4 CPU clock rate ≥2.8GHz, be able for extension
5.5 Main memory ≥2GB, be able for extension
5.6 Color LCD monitor 24”
5.7 Keyboard and mouse Standard
5.8 Hard disk ≥250GB, be able for extension
5.9 Media driver CRW / DVD
5.10 DICOM 3.0 Yes
5.11 Ethernet Yes
6 Scanning parameter
6.1 Max. FOV 400mm
6.2 Min. FOV 20mm
6.3 Min. 2D Thickness 1mm
6.4 Min. 3D thickness 0.1mm
6.5 Max. Image matrix 1024*1024
7 Scanning sequence &imaging technology
7.1 Spin echo 2D/3D (SE 2D/3D) Yes
7.2 Multi-slice multi-echo(MSME) Yes
7.3 Gradient echo(GRE 2D/3D) Yes
7.4 Steady state process gradient echo( SSPGRE) Yes
7.5 Fast spin echo (FSE) Yes
7.6 Fast double echo(FDE) Yes
7.7 Fast recover fast spin echo(FRFSE) Yes
7.8 Single shot fast spin echo(SSFSE) Yes
7.9 Multi shot fast spin echo (MSFSE) Yes
7.10 Inversion recovery (IR) Yes
7.11 Inversion recovery fast spin echo (IRFSE) Yes
7.12 Short time inversion recovery (STIR) Yes
7.13 Fluid attenuated inversion recovery (FLAIR) Yes
7.14 Gating technology Yes
7.15 Breath holding scan Yes
7.16 TOF 2D MRA Yes
7.17 TOF 3D MRA Yes
7.18 Diffusion weighted imaging (DWI) Yes
7.19 Max. b Value 1000s/mm2
7.20 Magnetization transfer (MTC) technology Yes
7.21 MIP Yes
7.22 MinIP Yes
7.23 3D position Yes
7.24 Pre-saturation technology (PS) Yes
7.25 Pre-saturation adjustment technology Yes
7.26 Part metal implant scan technology Yes
7.27 Automatic coil tuning Yes
7.28 MRM Yes
7.29 MRU Yes
7.30 MRCP Yes
7.31 Online image filtration Yes
7.32 Online post procession Yes
7.33 Optimal algorithm of active shimming Yes
7.34 Scan sequence queuing Yes
7.35 Multi-layer and multi-angle scanning technology Yes
7.36 Optimize bandwidth acquisition technology Yes
7.37 Flow compensation Yes
7.38 Parallel acquisition technology Yes
7.39 Section acquisition technology Yes
7.40 Scan parameter preset Yes
7.41 Oversampling technology Yes
7.42 Image fusion technology Yes
7.43 Artifact suppression technology (K_Rotat) Yes
7.44 Thin imaging technology Yes
7.45 Movie playback technology Yes
7.46 Post processing package Yes
4. BTI-042 Configuration
Standard Configurations Unit Quantity
Standard Hardware include:
RF shielding room set 1
Permanent Nd-Fe-B magnet, Full open C-shaped eddy current-free self-consistent temperature magnet set 1
Spectrometer pc 1
Preamplifier set 1
RF amplifier pc 1
Flat panel transmitter coil set 1
Gradient amplifier pc 1
Gradient coil set 1
Computer set 1
Imaging monitor set 1
Operation table set 1
Cover and diagnostic bed set 1
Head coil set 1
Neck coil set 1
Small body coil set 1
Large body coil set 1
Knee coil set 1
Shoulder coil set 1
Wrist coil Set 1
bed pats set 1
Quality control water phantom pc 1
MRI safety marks set 1
Technical manual pc 1
User manual pc 1
Maintenance manual pc 1
3-phase AC voltage stabilizer pc 1
Magnet self-consistent temperature system set 1
Dual-voice-communication system set 1
Patient bed laser location system set 1
Standard Software include set 1
Imaging software set 1
Pulse sequence set 1
Imaging enhancement software set 1
DICOM interface software set 1
Cardiovascular imaging software set 1
Diffusion functional imaging system package set 1
(MR CINE)/ MR CINE set 1
Accident analyzing software set 1
Quality control software set 1
Optional Modules Unit 1
Remark: RF shielding room are including RF shielding room decoration, RF shielding door, observation window, transmission board, Waveguide plate, interior lighting; excluding room construction and flooring, outside decoration of RF shielding room, operation room, equipment room, air-conditioner room and air-conditioner, external electric access and independent ground lead.
Basda will provide the technical staff for installation, including RF shielding room installation, MRI system installation, and training; The buyer shall bear round trip air ticket from China to installation country, local transportation, food and board of Basda's technicians in country of installation for the purpose of installation, training and service.
Contents are subject to change without prior notice
5. Service
Basda come to the market since 2000, got great improvement in service, gradually establish a set of mature service strategy, including
Three-level service network
1. Local partner engineer: primary diagnosing + in site maintenance
2. Basda service engineer: remote technical support + in site service (in case necessary)
3. Basda R&D center: technical support
Spare parts
1. Inventory is always ready
2. Delivery by express: within 2 working days pack off
3. Engineer carry-on: For big issue engineer will be in site with the spare parts service
6. Training plan
Training plan including the following items
1. Operation training: how to use?
2. Technical training: how it works?
3. Service training: how to test?