Home ProductsSuperconducting MRI

Strong Gradient RF 1.2 Tesla Superconducting MRI Machine BSTAR-120

Strong Gradient RF 1.2 Tesla Superconducting MRI Machine BSTAR-120

  • Strong Gradient RF 1.2 Tesla Superconducting MRI Machine BSTAR-120
  • Strong Gradient RF 1.2 Tesla Superconducting MRI Machine BSTAR-120
Strong Gradient RF 1.2 Tesla Superconducting MRI Machine BSTAR-120
Product Details:
Place of Origin: China
Brand Name: BASDA
Certification: CE, ISO13485
Model Number: Bstar-120
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiable
Packaging Details: 1 unit/wooden box
Delivery Time: 30-45 Days
Payment Terms: Credit card, Paypal, T/T, Western Union, MoneyGram
Supply Ability: 200 Machines per Year
Contact Now
Detailed Product Description
Magnet Shape: Bore Noise: Low
Magnet: Superconducting Application: Whole Body
Cooling Material: Liquid Helium Magnet Vertical Gap: 60 Cm
High Light:

Strong Gradient RF Superconducting MRI Machine

,

1.2 Tesla Superconducting MRI Machine

,

1.2 Tesla full body mri machine

BSTAR-120 full body bore type superconducting MRI low liquid helium 4k cold head strong gradient RF low noise 

The only 1.2T superconducting MRI is from Basda
 

The system is a new generation of superconducting MRI product has the advantages in novel design, excellent performance, high comfort and more patient care technology. The system adopts the international advanced hardware platform together with ergonomic operating software design, its advanced scan sequences and imaging technology, produces the customer with high stability and excellent performance, high signal-to-noise ratio, high resolution, high contrast clinical imaging and faster scanning speed.

 

 
Gradient System
 
The linearity of gradient system of MRI system determine the accuracy of spatial location information, ensuring that in any acquisition, the image distortion is limited.
 
Gradient switching rate is an important factor of MRI scanning speed. Bstar-120 using the self-shielding gradient coil and high duty cycle gradient amplifier system, together with eddy elimination technology and design, can avoid the eddy current between the metal shielding layers, raise up the spatial encoding ability of the magnetic resonance signal and make the scan more precise, ensure high resolution image quality.
 
During superconducting MRI scans, the noise is much bigger than permanent MRI systems, and staying in a closed environment, the patient is easy to fall into tension. Bstar-150’s gradient sub system adopts special hardware noise reduction design technology, the gradient noise is reduced to 2/3, provide patients with friendly scanning environment.
 
The gradient system is equipped with automatic detection function, if the temperature is too high, the system can intelligently stop the scanning, to protection of hardware from being damaged.
 
The system use water chiller to produce a stable running condition.
 
 
RF sub system
 
The RF sub system is the source of MRI proton excitation energy, its efficiency directly affects the MRI relax signal. RF receiver receive MRI relax signal, a good receiving coil can improve the SNR of image.
 
The RF sub system is similar as highway lane, the more lanes, the faster flow of vehicles. Vice versa, the more the RF system channels, the faster parallel acquisition, thus the system can process the greater the amount of data in the same time, reduce the imaging time. Bstar-150 suing 8 / 16 channel radio frequency receiving, combined with the latest parallel sampling technology, using the DDC digital direct sampling, can short the scan time and get excellent image quality.
 
 

Software

 

Bstar-120 provides comprehensive scan kit and scanning sequence, with rich clinical application of the full body, with a full range of scan plan, assist the customer’s clinical diagnosis. Advanced scanning sequence are provided as well as all routine scan, the system also can take vascular imaging, includes a broad range of capabilities supporting fast, accurate diagnosis of brain conditions and injuries. From anatomical depiction to vascular 3D reconstruction.

 

By adopting the brand-new phase array coil and scan control software, application of parallel acquisition accelerating technique, improve most sequence scanning speed, on the premise of image quality guarantee, accelerating factor can reach 2 or more as the maximum. The system keeps pace with international design and research, keeps improving the present clinical functions to provide lifetime free software upgrade for its users as well as let the hospital enjoy the most advanced MRI clinical application techniques.

 

K_Rotat artifact erasing technique, by using stripped K space rotating filling method to complete acquisition, can completely erase the effect of movement artifact on images and greatly improve SNR at the same time to provide guarantee for accurate diagnosis.

 

It provides a versatile suite of imaging capabilities for body imaging to meet the growing demands of abdominal, pelvic, and breast exams. Including MRU/MRCP/MRM imaging, and other advanced imaging sequences. Rich post-processing software can optimize images in case necessary to help in complex diseases diagnosis, excellent image quality and abundant imaging techniques.

 

Workflow is critical to the efficient operation of an MRI. It impacts patient satisfaction, image quality and cost effectiveness. It provides full preset of clinical diagnostic scan protocol, based on rich clinical experience, corresponding arrangement and optimization have been made per related clinical application features for the scan procedure and sequence parameters of the preset scan method. With unmatched clinical capability, and it provides an unprecedented ability to acquire complete exams with a motion compensated scan technique.

 

For restless patients and those who can’t cooperate, the preset extremely fast scan sequence can be used, which is very appropriate for fetus, newborns and infants.

 

High resolution isotropic diffusion imaging, based on powerful gradient system and amplifier system, it realizes faster and more reliable DWI images with high resolution, anatomic structure of head is clear, diffusion image features is obvious, very convenient for lesion location lock and lesion nature diagnosis.

 

Fast high-resolution abdomen diffusion imaging, under the support of brand-new parallel acquisition technique, realizes abdomen diffusion imaging with high spatial resolution, high time resolution and high contrast resolution, providing excellent tool of abdomen cancer diagnosis.

 

Extremely HD 3D TOF blood vessel imaging, optimized K space acquisition and filling method, suppression uniform of obtained images background, no artifact, clear blood vessel trend, can display tertiary vascular or above.

 

Strong Gradient RF 1.2 Tesla Superconducting MRI Machine BSTAR-120 0

 

Interactive environment

  • Motor-driven patient table, 200kg weight capacity.
  • Built-in-magnet high resolution 8 inch screen, the operation is convenient.
  • Have emergency stop function, protect the patients.
  • High positioning accuracy.
  • Support operation on both sides of the magnet, convenient and quick.
 

E-alarm technology

 

At the same time, in Bstar-120 configuration there is a special monitoring system, it is simple and easy to operate, it can real-time monitoring the magnet internal pressure, temperature and liquid helium level, if the magnet condition is abnormal, the monitoring system can automatically send alarm information to the user's phone, it can greatly reduce the risk of magnet quenches.

 

 

Water chiller set

Intelligent touch screen design, visual operation, and be convenient for maintenance.

 

1, automatic overheating, leaking, fault detection, safe and reliable.

2, one key recovery function.

3, config with a set of spare water chilling unit, no need to have any worry about the system downtime.

 

Contact Details
Shenzhen Basda Medical Apparatus Co., Ltd

Contact Person: Peng

Tel: +86-13632708845

Send your inquiry directly to us (0 / 3000)

Contact

Address: Floor 19, Block 1A, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.

Factory Address:Block 1B, Basda Building, No. 28 Nantong Road, Longgang District, Shenzhen, Guangdong Province, P.R.C.